top of page

Can Wearables Measure Hormones? The Science Behind Hormone Tracking Technology

Aaqifah Hilmi
4 hours ago
9 min read

Wearables can measure hormones when they contain dedicated biochemical sensors, and research prototypes have demonstrated cortisol and oestradiol detection in sweat. However, familiar smart-ring and smartwatch features usually track physiological signals influenced by hormones, such as temperature, heart-rate variability, sleep and respiration. These signals can support useful estimates of stress responses or menstrual-cycle patterns, but they do not directly reveal hormone concentrations. Sweat sensors and minimally invasive interstitial-fluid sensing could expand wearable hormone monitoring, provided their accuracy, reliability and intended health applications are validated.


Your ring notices a temperature shift. Your watch estimates when you ovulated. Another app reports a stressful day. It is easy to connect these features with the hormones influencing your body.


But what has the device actually measured?


That question sits at the centre of hormone tracking technology. A sensor can observe the effects of a hormonal change without detecting the hormone itself. Understanding the difference helps users interpret their data and helps product teams decide what evidence their device needs.


Can Wearables Measure Hormones? The Science Behind Hormone Tracking Technology
AI generated image

Can Wearables Measure Hormones Directly?


Yes, with the right sensing system. Researchers have demonstrated skin-worn devices that detect specific hormones in biological fluids. A 2022 study, for example, developed an aptamer-based cortisol sensor integrated into a smartwatch-style research platform. Its hormone measurement came from a biochemical sensing interface, rather than an ordinary pulse sensor.¹


There are three distinct outputs worth separating:


Output

What the device does

Example

Physiological measurement

Records a bodily signal

Overnight finger temperature

Hormone-related inference

Interprets patterns associated with hormonal changes

Estimated cycle phase

Biochemical measurement

Detects a target hormone in a specified fluid

Cortisol concentration in sweat


Think of the difference as watching leaves move versus measuring wind speed. Moving leaves provide useful evidence, but their movement also depends on the tree, its shelter and other conditions. A hormone-related signal similarly needs context.


Why Are Hormones Difficult to Measure Directly?


Hormones are chemical messengers. Measuring them requires identifying particular molecules among many other substances, often at very low concentrations.


The sensor must recognise the right molecule


A conventional optical pulse sensor detects changes in light associated with blood-volume changes. It does not become a hormone sensor simply because an algorithm analyses its readings.


Biochemical sensors instead need a recognition mechanism. In the cortisol research platform, an aptamer, i.e., a selected nucleic-acid sequence that binds a target, provided molecular recognition, which was converted into an electrical signal. It is rather like finding one person in a crowded station. Detecting that a crowd exists is easier than reliably identifying a particular individual.


The sampled fluid changes the meaning


A sweat measurement describes sweat. A blood measurement describes blood. Results from different fluids cannot automatically share the same interpretation or reference range.


The cortisol study investigated relationships between sweat and saliva, but establishing a relationship does not make the samples interchangeable. Developers must validate both the measurement in its own fluid and any claim about what it represents elsewhere in the body.


Timing matters as much as concentration


Hormone readings also need a clock. In clinical cortisol assessment, sampling protocols may involve late-night saliva or urine collected over 24 hours; the timing serves a specific diagnostic purpose.²


A wearable promises a richer timeline, but every point still needs a defined sample, timestamp and interpretation. More frequent readings are useful only when they remain trustworthy.


Why Do Hormone Tracking Wearables Use Proxy Signals?


Physical sensors can collect repeated measurements with relatively little effort from the wearer. Temperature sensors, optical pulse sensing and accelerometers are already practical components of rings and watches.


These measurements can reveal recurring patterns associated with hormonal physiology. They also avoid the fluid collection and molecular-recognition hardware required for biochemical monitoring.


The trade-off is specificity. The same physiological pattern can have several explanations. Combining signals may help an algorithm identify a pattern, but it does not automatically establish which hormone caused it or how much of that hormone is present.


A useful hormone-related feature therefore begins with a narrow question, such as identifying a cycle-related temperature pattern, rather than promising a complete picture of “hormone balance.”


For users, the most useful first step is to read the feature description. Does the result represent a measured concentration, an estimated event or a general physiological score? Those categories support different decisions. Keeping a record of symptoms and relevant daily context can also make trends easier to discuss, without assuming the wearable has identified their underlying cause.


HRV, Temperature, Sleep and Respiration: What Can They Tell Us?


HRV and heart rate: cardiovascular context


Heart-rate variability, or HRV, describes variation in the time between successive heartbeats. Wearables use it alongside other signals to characterise physiological responses.


For example, Oura’s Daytime Stress feature combines heart rate, HRV, movement and temperature against a personal baseline. Its documentation describes physiological stress, which can arise from different causes.³


A change in HRV is therefore not a cortisol result. It is more like a dashboard warning light: it may draw attention to a change, but it does not identify every mechanism behind it. A predicted hormone value would require separate validation against hormone measurements.


Temperature: a useful clue to reproductive physiology


Progesterone-related temperature changes provide one of the clearest examples of hormone-informed wearable tracking. Oura explains that the post-ovulation luteal phase usually involves an elevated temperature pattern and uses temperature deviations for cycle insights.⁴


The ring is measuring temperature at the finger. It is not reporting a progesterone concentration. A sustained pattern can support cycle interpretation without establishing whether progesterone meets a clinical threshold.


Sleep: useful context, limited specificity


Sleep timing and continuity can help describe daily patterns, but a poor night does not identify a hormone deficiency or excess.


Importantly, different wearable signals need not change together. A 2024 study involving young and midlife participants reported menstrual-cycle variations in finger temperature and heart rate, but not corresponding variations in its wearable sleep metrics.⁵


That finding cautions against treating every sleep fluctuation as a hormonal event. The absence of a sleep change also does not establish that hormones remained unchanged.


Respiration: another supporting signal


Respiratory rate can add context to cycle-related physiology. A large wearable study analysed resting heart rate, HRV, respiration, temperature and other metrics across menstrual cycles, finding cycle-associated patterns alongside effects related to sleep duration.⁶


These overlapping influences matter. An overnight breathing-rate change cannot, by itself, identify a progesterone level or prove a hormonal explanation.


Stress and Cortisol: Why a Stress Score Is Not a Hormone Test


Cortisol is a useful example because both biochemical sensors and physiological stress algorithms are described using similar everyday language.


An ordinary wearable stress feature interprets bodily responses. A cortisol biosensor targets a molecule in a sample. Neither output, on its own, fully explains why someone feels stressed.


Clinical investigation of suspected cortisol disorders involves specific testing protocols. NIDDK describes urine, saliva and blood testing for Cushing’s syndrome, sometimes followed by further tests to establish the cause. A consumer stress score does not provide that assessment.


For a deeper explanation of sweat sampling, cortisol timing and stress biomarkers, see Sensio’s Can Wearables Detect Cortisol Levels?


Reproductive Hormone Tracking: Cycle Estimates Versus Concentrations


Commercial cycle tracking illustrates how useful inference can be when its purpose is clearly defined.


Apple documents retrospective ovulation estimates based on the temperature shift that can occur after ovulation, combined with logged cycle information. It also states that these estimates do not guarantee ovulation occurred and that Cycle Tracking should not be used for diagnosis or birth control.⁷


Oura similarly uses physiological patterns for cycle insights. These features should not be described as direct oestrogen or progesterone testing. Product availability and capabilities also depend on the market and device.


Biochemical reproductive-hormone sensing takes a different approach. A study published online in 2023 and appearing in Nature Nanotechnology in 2024 demonstrated a wearable aptamer nanobiosensor for oestradiol analysis in sweat.⁸


This is evidence that a dedicated wearable can detect a reproductive hormone. It does not establish that every cycle-tracking ring measures oestradiol, or that experimental sweat readings can replace blood testing across fertility treatment and other clinical uses.


Can Sleep Wearables Measure Melatonin?


Sleep detection and melatonin measurement answer different questions. One concerns behaviour and physiological patterns during the night; the other concerns a particular chemical signal associated with circadian timing.


Researchers often assess circadian phase using dim-light melatonin onset, or DLMO: the timing of melatonin’s rise under controlled dim-light conditions. This requires repeated biological samples and laboratory analysis.


Research has also explored estimating DLMO from sleep timing, light exposure, skin temperature and activity. A study using data from 207 undergraduates demonstrated a computational approach combining measurements across different timescales.⁹


Such a model estimates timing. It does not mean a sleep tracker is continuously measuring melatonin concentration. Like estimating sunrise from a room gradually brightening, indirect clues can be informative while remaining sensitive to the surroundings.


The Future of Sweat-Based Hormone Monitoring


Sweat offers an accessible route to biochemical sensing without drawing blood. The oestradiol research shows how molecular recognition and wearable sampling can work together.


A practical system needs to collect fluid, bring it to the sensing surface, distinguish its target and translate the response into a calibrated result. Some research designs stimulate local sweating rather than relying on exercise.


The difficult question is whether the system can deliver fresh, interpretable samples throughout its intended use. A patch that works during a demonstration must still be evaluated during quiet activity, changing temperatures and repeated wear.


“Continuous” also needs a precise definition. Developers should establish how frequently fresh samples arrive, whether concentrations can be followed as they rise and fall, and how long performance remains acceptable.


An encouraging sensing result is the beginning of that evidence, rather than the complete case for an everyday hormone monitor.


Interstitial Fluid Sensing and Microneedle Wearables


Interstitial fluid is the fluid surrounding cells in tissue. Microneedle systems access it through small structures that penetrate the skin, making this a minimally invasive approach rather than a completely non-invasive one.


A 2022 human study demonstrated an integrated microneedle wearable for monitoring combinations of glucose, lactate and alcohol in interstitial fluid during everyday activities.¹⁰ These targets were metabolites, not hormones.


The distinction matters: demonstrating a fluid-access platform does not establish that it can measure any molecule. Hormone monitoring still requires a suitable sensing chemistry, sensitivity and validation for the specific target.


Think of microneedles as providing access to a room. Getting through the door does not tell you whether your equipment can identify what is inside. The access method and analytical method must both work.


What Should Teams Validate Before Building a Hormone Wearable?


For product teams, a useful development plan separates three questions.


Does it measure the intended hormone? Compare the sensor with an appropriate laboratory method for the same fluid. Assess interference, repeatability, concentration range and changes over the intended wear period.


Does it work in the intended setting? Evaluate sample availability, movement, comfort, missing readings and the effects of repeated use. A sensor intended for overnight monitoring needs overnight evidence.


Does the result support the intended application? Detecting a hormone in sweat is a different claim from identifying ovulation, diagnosing an endocrine condition or guiding treatment. Each requires evidence matched to its purpose.


For inferred outputs, evaluation should include people whose data were not used to train the model. Reports should explain uncertainty and unavailable readings. A helpful product must communicate when the evidence is insufficient to produce a dependable result.


The Future of Wearable Hormone Monitoring


Wearable hormone monitoring will likely develop through complementary approaches: physiological signals that help identify patterns, and biochemical sensors that measure selected molecules.


The opportunity is to understand changes over time with less sampling burden. The standard remains clear: state what was measured, which fluid or signal produced it, and what conclusions the evidence supports.



Explore Hormone Biomarker Research with Sensio


Sensio welcomes research collaborations exploring hormone-related biomarkers and wearable sensing. If your team is investigating how biochemical measurements could complement temperature, cardiovascular signals or sleep data, connect with us to discuss the research question, device concept and validation pathway.



References:

  1. Wang B, Zhao C, Wang Z, Yang KA, Cheng X, Liu W, Yu W, Lin S, Zhao Y, Cheung KM, Lin H, Hojaiji H, Weiss PS, Stojanović MN, Tomiyama AJ, Andrews AM, Emaminejad S. Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring. Sci Adv. 2022 Jan 7;8(1):eabk0967. doi: 10.1126/sciadv.abk0967. Epub 2022 Jan 5. PMID: 34985954; PMCID: PMC8730602. 

  2. U.S. Department of Health and Human Services. (n.d.-a). Cushing’s syndrome - NIDDK. National Institute of Diabetes and Digestive and Kidney Diseases. https://www.niddk.nih.gov/health-information/endocrine-diseases/cushings-syndrome

  3. Daytime stress. Oura Member Care. (n.d.-a). https://support.ouraring.com/hc/en-us/articles/21205822135315-Daytime-Stress 

  4. Cycle insights. Oura Member Care. (n.d.-a). https://support.ouraring.com/hc/en-us/articles/4410663885331-Cycle-Insights 

  5. Alzueta E, Gombert-Labedens M, Javitz H, Yuksel D, Perez-Amparan E, Camacho L, Kiss O, de Zambotti M, Sattari N, Alejandro-Pena A, Zhang J, Shuster A, Morehouse A, Simon K, Mednick S, Baker FC. Menstrual Cycle Variations in Wearable-Detected Finger Temperature and Heart Rate, But Not in Sleep Metrics, in Young and Midlife Individuals. J Biol Rhythms. 2024 Oct;39(5):395-412. doi: 10.1177/07487304241265018. Epub 2024 Aug 6. PMID: 39108015; PMCID: PMC11416332. 

  6. Gonzalez, A., O’Day, J.J., Johnson, S.C. et al. The menstrual cycle through the lens of a wearable device: insights into physiology, sleep, and cycle variability. npj Digit. Med. 9, 633 (2026). https://doi.org/10.1038/s41746-026-02799-9 

  7. Receive retrospective ovulation estimates on Apple Watch - Apple Support (in). Apple Support. (n.d.-b). https://support.apple.com/en-in/120357

  8. Ye C, Wang M, Min J, Tay RY, Lukas H, Sempionatto JR, Li J, Xu C, Gao W. A wearable aptamer nanobiosensor for non-invasive female hormone monitoring. Nat Nanotechnol. 2024 Mar;19(3):330-337. doi: 10.1038/s41565-023-01513-0. Epub 2023 Sep 28. PMID: 37770648; PMCID: PMC10954395.

  9. Wan, C., Mchill, A. W., Klerman, E. B., & Sano, A. (2021). Sensor-based estimation of DIM light melatonin onset using features of two time scales. ACM Transactions on Computing for Healthcare, 2(3), 1–15. https://doi.org/10.1145/3447516

  10. Tehrani F, Teymourian H, Wuerstle B, Kavner J, Patel R, Furmidge A, Aghavali R, Hosseini-Toudeshki H, Brown C, Zhang F, Mahato K, Li Z, Barfidokht A, Yin L, Warren P, Huang N, Patel Z, Mercier PP, Wang J. An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid. Nat Biomed Eng. 2022 Nov;6(11):1214-1224. doi: 10.1038/s41551-022-00887-1. Epub 2022 May 9. PMID: 35534575.


Comments